Model | DSO5202P | |
Acquisition | ||
Sample Rate | Real-Time Sample: 1GS/s | |
Acquisition Modes | ||
Normal | Normal data only | |
Peak Detect | High-frequency and random glitch capture | |
Average | Waveform Average, selectable 4,8,16,32,64,128 | |
Inputs | ||
Inputs Coupling | AC, DC, GND | |
Inputs Impedance | 1MΩ±2% ‖20pF±3pF | |
Probe Attenuation | 1X, 10X | |
Supported Probe Attenuation Factor | 1X, 10X, 100X, 1000X | |
Maximum Input Voltage |
CAT I and CAT II: 300VRMS (10×), Installation Category; |
|
Horizontal System | ||
Sample Rate Range | 500MS/s--1GS/s | |
Waveform Interpolation | (sin x)/x | |
Record Length | 40k | |
SEC/DIV Range | 2ns/div to 40s/div | |
Sample Rate and Delay Time Accuracy | ±50ppm(at over any ≥1ms time interval) | |
Position Range | 2ns/div to 10ns/div; (-4div x s/div) to 20ms; |
|
Delta Time Measurement Accuracy(Full Bandwidth) | Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200 |
|
Vertical System | ||
Vertical Resolution | 8-bit resolution, all channel sampled simultaneously | |
Position Range | 2mV/div to 10V/div | |
Bandwidth | 200MHz | |
Rise Time at BNC(typical) | 1.8ns | |
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled | 2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V; 5V/div, ±50V |
|
Math | +, -, *, /, FFT | |
FFT | Windows:Hanning,Flatop, Rectamgular,Bartlett,Blackman; 1024 sample point |
|
Bandwidth Limit | 20MHz | |
Low Frequency Response(-3db) | ≤10Hz at BNC | |
DC Gain Accuracy | ±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div |
|
DC Measurement Accuracy, Average Acquisition Mode | When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div |
|
Volts Measurement Repeatability, Average Acquisition Mode | Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions | |
Trigger System | ||
Trigger Types | Edge, Video, Pulse, Slope, Over time, Alternative | |
Trigger Source | CH1, CH2, EXT, EXT/5, AC Line | |
Trigger Modes | Auto, Normal, Single | |
Coupling Type | DC, AC, Noise Reject, HF Reject, LF Reject | |
Trigger Sensitivity(Edge Trigger Type) | DC(CH1,CH2): 1div from DC to 10MHz;1.5div from 10MHz to 100MHz; 2div from 100MHz to Full; DC(EXT): 200mV from DC to 100MHz; 350mV from 100MHz to 200MHz; DC(EXT/5): 1V from DC to 100MHz;1.75V from 100MHz to 200MHz; AC: Attenuates signals below 10Hz; HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz |
|
Trigger Level Range | CH1/CH2: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6V |
|
Trigger Level Accuracy(typical) Accuracy is for signals having rise and fall times >=20ns | CH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen; EXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV); |
|
Set Level to 50%(typical) | Operates with input signals ≥50Hz | |
Video Trigger | ||
Video Trigger Type | CH1, CH2: Peak-to-peak amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V |
|
Signal Formats and Field Rates, Video Trigger Type | Supports NTSC, PAL and SECAM broadcast systems for any field or any line | |
Holdoff Range | 100ns ~ 10s | |
Pulse Width Trigger | ||
Pulse Width Trigger Mode | Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse | |
Pulse Width Trigger Point | Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Less than: The trigger point is the trailing edge. Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width |
|
Pulse Width Range | 20ns ~ 10s | |
Slope Trigger | ||
Slope Trigger Mode | Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope | |
Slope Trigger Point | Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope. |
|
Time Range | 20ns ~ 10s | |
Overtime Trigger | ||
Over Time Mode | Rising edge or Falling edge | |
Time Range | 20ns ~ 10s | |
Alternative Trigger | ||
Trigger on CH1 | Internal Trigger: Edge, Pulse Width, Video, Slope | |
Trigger on CH2 | Internal Trigger: Edge, Pulse Width, Video, Slope | |
Trigger Frequency Counter | ||
Readout Resolution | 6 digits | |
Accuracy (typical) | ±30ppm (including all frequency reference errors and ±1 count errors) | |
Frequency Range | AC coupled, from 4Hz minimum to rated bandwidth | |
Signal Source | Pulse Width or Edge Trigger modes: all available trigger sources The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed. Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time. Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity. Video Trigger mode: The Frequency Counter does not work. |
|
Measurement | ||
Cursor Measurement | Voltage difference between cursors: △V Time difference between cursors: △T Reciprocal of △T in Hertz (1/ΔT) |
|
Auto Measurement | Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Period Mean, Period RMS, FOVShoot, RPREShoot, BWIDTH, FRF, FFR, LRR, LRF, LFR, LFF | |
Display | ||
Display Type | 7 inch 64K color TFT (diagonal liquid crystal) | |
Display Resolution | 800 horizontal by 480 vertical pixels | |
Display Contrast | Adjustable (16 gears) with the progress bar | |
Probe Compensator Output | ||
Output Voltage (typical) | About 5Vpp into ≥1MΩ load | |
Frequency(typical) | 1kHz | |
Power Supply | ||
Supply Voltage | 100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ 120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ |
|
Power Consumption | <30W | |
Fuse | 2A, T rating, 250V | |
Environmental | ||
Temperature | Operating: 32℉ to 122℉ (0℃ to 50℃); Non-operating: -40℉ to 159.8℉ (-40℃ to +71℃) |
|
Cooling Method | Convection | |
Humidity | +104℉ or below (+40℃ or below): ≤90% relative humidity; 106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity |
|
Altitude | Operating: Below 3,000m (10,000 feet); Non-operating: Below 15,000m(50,000 feet) |
Frage Antwort
Diskussionen
Bitte beachten Sie, dass TOMTOP Forum eine Community für Ideenaustausch und Hilfe sucht, bei denen Tech-Enthusiasten an der Diskussion teilnehmen werden, mittlerweile wird TOMTOP Kundenservice (mit Tomtop Kundenservice-Symbol) rechtzeitig reagieren, mit der gleichen Funktion wie der Kontakt auf http : //www.tomtop.com/contacts