DCA Range | 1mV / 10mA | ±(1.5%±5mA) 10mA ~ 20A |
1mV/100mA |
±(2%±20mA) 100mA ~ 40A; ±(4%±0.3A) 40A ~ 65A |
|
ACA Range | 1mV/10mA |
±(2%±30mA) 100mA ~ 10A (40Hz ~ 2KHz); ±(4%±30mA) 100mA ~ 10A (2KHz ~ 10KHz); ±(6%±30mA) 100mA ~ 10A (10KHz ~ 20KHz); ±(8%±30mA) 10A ~ 15A (40Hz ~ 20KHz) |
1mV/100mA |
±(2%±30mA) 200mA ~ 40A (40Hz ~ 1KHz); ±(4%±30mA) 200mA ~ 40A (1KHz ~ 2KHz); ±(6%±30mA) 200mA ~ 40A (2KHz ~ 5KHz); ±(8%±0.3A) 40A ~ 65A (40Hz ~ 20KHz) |
|
Captured Conductor Size | Max. 9mm | |
Low Battery Indicator | Red LED Lighting | |
Operating Temperature | 0°C to 50°C, 70% RH | |
Storage Temperature | -20°C to +70°C, 80% RH | |
Battery Type | 1 * 9V 6F22 Battery (NOT Included) | |
Output | BNC Plug | |
Dimensions | 195 * 70 * 33mm / 7.67 * 2.75 * 1.3in | |
Weight | 184g / 6.5oz | |
Package Size | 21.5 * 11 * 5cm / 8.46 * 4.33 * 1.97in | |
Package Weight | 251g / 8.85oz |
Questions & Answers
I am using it with a different scope so it will wprk with Rigol too.
By Ion54 on September 10, 2017
For cables like battery cables you need the CC650 that is from Hantek!!
By Jonathan Vargas on April 17, 2018
That is exactly what it is designed to do. I have this clamp and it works well!
By Michael Regan on April 11, 2018
hi,dear Adam We are afraid you need specify which kind of plug you prefer, we can provide BNC or BANADA, you need inform us your requirement after purchase, hope this helped, thanks!
By Arredondo on April 8, 2018
Normal starter draw is usually around 100 amps with a high spike on initial turn on, athough i have seen youtube seminar videos that show an 80A pickup being used, the cc65 however can be used for lower amperage circuit/motor testing... Fuel pump... Window motors, fuel injectors
By aLAN L. on February 18, 2018
The size of the circular openings is about 10mm in diameter. Accuracy would be affected if the jaws are not fully closed. Hope this has answered your question.
By Arline on February 17, 2018
cc-65
By Tom K. on February 22, 2018
Yes, just please consider the range comply with your scope.
By Dante on January 17, 2018
It works with any scope with standard BNC connectors including your Hantek 6022BE. Thanks.
By Akiyo Tona on September 23, 2017
hi..where did you saw such information? this current clamp meassure AMPS ( 20Ma to 65A) not volts or millivolts. I used it with my oscilloscope and DSO with great success.
By Pablo C. on September 10, 2017
Discussions
Please note that TOMTOP Forums are a community for all communicating and getting help each other. There will be some enthusiastic friends participate in your discussions. Of course TOMTOP customer service (with tomtop customer service icon) response is guaranteed ,which is the same way you contact us at http://www.tomtop.com/contacts
open this forum in full pageAverage Rating:
4.3based on 8 Customer Reviews
Share your thoughts with other customers and get Tomtop Points, the first 5 reviews get DOUBLE Tomtop Points!
Write a Customer ReviewBy t***9
May 31, 2018
By b***y
April 18, 2018
By s***4
January 11, 2018
By T***1
November 27, 2017
By e***z
September 6, 2017
By p***d
September 5, 2017
By r***0
August 5, 2017
By w***1
December 1, 2015